Building and Equipment
The delivery of the JOULE BIOGAS firm comprises all systems, subsystems, assembly groups and components that are necessary for the operation of the JOULE BIOGAS plant.
Building, aids and machines that are not part of the Joule Biogas technique are provided by the customer (e. g. caterpillar, cleaning machines).
Building
Concrete-thickness of the fermenter:
| |
thickness of the sides: |
20 cm |
| |
thickness of the ceiling: |
22 cm |
| |
thickness of the floor: |
30 cm |
Dimension of the fermentation tank (inside dimensions):
| |
length: |
30 m |
| |
breatdth: |
6 m |
| |
height: |
4 m |
Dimension of the modul (outside dimensions):
| |
length: |
30,5 m |
| |
breadth: |
25 m |
| |
height: |
4 m |
Quality of the concrete:
| |
gastight; acid- proof, electrical leading |
|
Technique
Gas Production Area
-
fermenter, incl. heating system
-
gas carrier
-
gasmain, incl. Gas gauge
-
compressor
-
percolatsystem (microbiology)
-
biofiltersystem
Subsystems
-
lock-type thermal power unit: gas engine, generator, heat exchanger
-
delivery-Stations: electrical power, heat
-
measuring technique
-
lock-type thermal power unit: gas engine, generator, heat exchanger
-
delivery-Stations: electrical power, heat
-
measuring technique
Control-System
-
PC based SPC system
-
delivery-Stations: electrical power, heat
-
safety-system